Location: 1000 Parkwood in Marietta, GA and is the recent recipient of the prestigious 2010 TOBY Award (The Renovated Office Building of the Year).
Proposal:
Replace 104 - 175W parking garage and wall pack fixtures to 80W Induction and 6 - 400W HID Deck Top fixtures to 200W Induction.
Details:
Acheived 54% energy reduction
Reduced 108,000 KWH annually
Reduced energy costs by over $13,000 annually
Recued 92 tons of CO2
1.50 years ROI
|
|
Deck Top 400W HID to 200W Induction |
|
|
|
Exterior Ramp 400W HID to 200W Induction |
|
|
|
Garage 150W HPS to 80W Induction |
|
|
|